Physical Characteristics
• Height: 138.2 cm (54.4 inch)
• Width: 51.8 cm ( 20.4 inch)
• Depth: 88.0 cm (34.6 inch)
• Weight: 102 kg (225 pounds) without OEM’s User Interface
• Intuitive PC-based operating principles
• User-centric control panel with HomeBase layout
• On/Off task light and back-lit illumination of control panel
• Up to 32 QuickSet™ user-programmable system parameters allow users to program system parameters for individual transducer/application settings. QuickSet parameters combine all preferred imaging mode parameters, annotation text and measurements into one user preset Monitor
• Flat Panel Display, 15-inch color, high resolution, and progressive scan (non-interlaced) with in plane switching (IPS) technology
• Resolution, 1024 x 768 pixels
• Total screen area 1024 x 768. Recordable image area clips 800 x 600. Total screen capture is an option Hard Drive
• Internal 80 GB hard drive for patient database management DVD Dual Drive (DVD-R/RW & CD-R/RW)
• Removable 650 MB, 700 MB and 790 MB CD-R and 650 MB or 700 MB CD-RW
• Removable 4.7 GB single layer DVD and 8.5 GB single side double layer DVD
• Allows storage and archiving of complete patient studies including images, dynamic clips, reports and measurements
Transducer Ports
• Up to three active universal transducer ports that support phased array, curved array and linear array transducers (3rd array port optional)
• The two transducer port configuration has two active and one transducer parking port
• Electronic transducer selection (instantaneous switching between transducers)
• Industrial design provides easy access to the transducer ports
Transducer Storage
• Six configurable transducer holders support all transducer designs and provide gel bottle storage
• SuppleFlex™ transducer cables and integrated cable management for protection during exams and transport
• Special transducer holder provides secure storage and easy access to endocavity transducer
• Transducer holders can be removed for cleaning
Operating/Display Modes
• 2D imaging in fundamental and harmonic modes (both phase inversion and filtered)
• DTI™ Doppler Tissue Imaging capability including 2D, M-mode and Spectral
• Color M-mode
• M-mode
• Color Doppler Velocity mode
• Power Doppler mode
• Directional power Doppler
• PW Pulsed Wave spectral Doppler mode
• CW Continuous Wave spectral Doppler mode (Aux Pencil style and phased array steerable)
• ECG trace in all modes
• Duplex mode
• Triplex mode
• Flexible combination of imaging modes in side-by-side Dual and Dual Select in real-time, and digital cine replay
• Selectable split screen display formats in 2D or 2D/color with M-mode and/or spectral Doppler mode: top-bottom or side-by-side in real-time and digital cine replay
• 4B mode
• Virtual Format 2D Calipers – Generic Measurements and Calculations
• Multiple cursor sets on frozen, live, dual screen and cine playback images
• Up to 8 distance measurements per screen
• Distance and depth measurement from skin line
• Angle measurement
• Area and circumference: ellipse, trace
• Compound Measurements:
- Volume: user-selectable preset by 1 distance, 2 distance, 3 distance; 1 ellipse and 1 distance
- Flow volume: 1 velocity and 1 distance, or 1 velocity and 1 ellipse
- Stenosis: user-selectable preset calculated by 2 ellipse, or 2 distance measurements Cine Review
Cine feature is standard and offers post-acquisition optimization of all real-time post-processing functions.
• Frame-by-frame cine loop review and continuous cine motion review, including
control of playback rate
• Independent cine review in mixed modes (2D/M, 2D/Doppler, 2D/C/Doppler)
• Independent cine review in 2D Dual Select mode with image align playback feature
• Maximum Standard Cine Memory is up to 545 frames
• Cine Store: Multiple single frame storage with clipboard review allowing post processing, measurement and annotation functions
• Retrospective clip capture during real-time imaging with a selectable duration of 1, 2, 3, or 4 seconds or a selectable duration 1, 2, 3 or 4 beat capture; ECG triggerable (for OB preset only 1 or 2 seconds and only 1 or 2 beats are
available)
• Prospective clip capture during real-time imaging with a selectable duration of 1 to 120 seconds a selectable duration 1 to 120 beat capture; ECG triggerable
Post Processing Features in Freeze Frame or Cine
• 2D-mode
- Zoom/pan
- Gray map
- 2D-mode colorization map
- Measurements/reports/annotations/pictograms
• Color
- Zoom/pan
- Color map
- Color invert
- Measurements/reports/annotations/pictograms
• Doppler
- Gray map
- Doppler colorization map
- Angle correct
- Measurements/reports/annotations/pictograms
• M-Mode
- Gray map
- M-mode colorization map
- Measurements/reports/annotations/pictograms
Transducer Technology
Ultra-sensitive, wideband transducers, matched with user-selectable MultiHertz multiple frequency imaging, improve resolution and penetration. Depending on the transducer, the user can select up to 7 2D and THI frequencies and up to 2 color and spectral Doppler frequencies, expanding the clinical versatility of a single transducer, and thereby maximizing transducer investment.
• Wideband MultiHertz imaging allows user selection of independent 2D and color frequencies for optimal resolution and penetration
• Universal, stainless steel and disposable biopsy guides for specified linear and curved array transducers
• Innovative ultra low-loss lens materials and microelectronic technologies for efficient performance and increased signal bandwidth
• Frequency range: 2.0 – 13.0 MHz
• Hanafy Lens acoustic technology
• MicroCase™ transducer miniaturization technology and SuppleFlex cables
Note: See dedicated transducer flyer for more information.
|